Abstract
Contrast variation method in small-angle neutron scattering (non-polarized neutrons) is,applied to magnetic fluids (MFs) with magnetite dispersed in benzene and coated with myristic or,oleic acid in zero external magnetic field. The basic functions approach for polydisperse,superparamagnetic systems is used to get structure parameters of particles in MFs.