@misc{snihirova_influence_of_2019, author={Snihirova, D., Lamaka, S.V., Gonzalez-Garcia, Y., Yilmaz, A., Scharnagl, N., Montemor, M.F., Zheludkevich, M.L.}, title={Influence of inhibitor adsorption on readings of microelectrode during SVET measurements}, year={2019}, howpublished = {journal article}, doi = {https://doi.org/10.1016/j.electacta.2019.134761}, abstract = {The results reveal the detrimental effect of some corrosion inhibitors on the sensitivity of the vibrating probe, an effect that imposes a regular assessment of the electrode state during measurements. The increase of the signal noise was related to a decrease of the probe capacitance, while the false current density signal was a result of the potential drift between vibrating and reference electrodes.}, note = {Online available at: \url{https://doi.org/10.1016/j.electacta.2019.134761} (DOI). Snihirova, D.; Lamaka, S.; Gonzalez-Garcia, Y.; Yilmaz, A.; Scharnagl, N.; Montemor, M.; Zheludkevich, M.: Influence of inhibitor adsorption on readings of microelectrode during SVET measurements. Electrochimica Acta. 2019. vol. 322, 134761. DOI: 10.1016/j.electacta.2019.134761}}