@misc{park_dobutamine_stress_2008, author={Park, J.-W., Leithaeuser, B., Vrsansky, M., Jung, F.}, title={Dobutamine stress magnetocardiography for the detection of significant coronary artery stenoses – A prospective study in comparison with simultaneous 12-lead electrocardiography}, year={2008}, howpublished = {journal article}, doi = {https://doi.org/10.3233/CH-2008-1064}, abstract = {Results: Without β-blocker all 100 patients reached the targeted heart rate. The image quality of DS-MCG and DS-ECG was sufficient for analysis in all patients. In 19 patients CAD was ruled out angiographically. Thirty two or seven patients revealed coronary artery stenoses of 30–49% or of 50–69%, respectively. In 42 patients we found significant stenoses of ≥70%. In 41 of these patients DS-MCG revealed myocardial ischemia. The sensitivity of DS-MCG and DS-ECG for the detection of significant coronary artery stenosis was 97.6% and 26.2%, the specificity of DS-MCG and DS-ECG 82.8% and 82.8%, respectively.}, note = {Online available at: \url{https://doi.org/10.3233/CH-2008-1064} (DOI). Park, J.; Leithaeuser, B.; Vrsansky, M.; Jung, F.: Dobutamine stress magnetocardiography for the detection of significant coronary artery stenoses – A prospective study in comparison with simultaneous 12-lead electrocardiography. Clinical Hemorheology and Microcirculation. 2008. vol. 39, no. 1-4, 21-32. DOI: 10.3233/CH-2008-1064}}